Value range:
Yes, No
Unit:
None
Content: Early Classmark Sending Control. It informs MS in
a cell whether class-mark 3 should be sent in advance actively or not.
Recommendation:
No.
Upon
receiving information classmark
change, MS sends the additional classmark information to the network as soon
as possible. CM3 (classmark 3)
information consists of information about the powers of various bands of
multi-band MS. In the handover between various bands, the power level must be
described correctly. CM3 message must be known when paging is conducted and BA2
table is sent in different bands. ECSC is valid mainly for dual-band MS only.
For dual-band MS, when ECSC
is not used, MSC will still send the CLASSMARK REQUEST message after MS reports
ESTIND. When MS reports the CLASSMARK UPDATE message, other functions will not
be affected.